Acoustic tweezers (also known as acoustical tweezers) are a set of tools that use sound waves to manipulate the position and movement of very small objects.[1] Strictly speaking, only a single-beam based configuration can be called acoustical tweezers. However, the broad concept of acoustical tweezers involves two configurations of beams: single beam and standing waves. The technology works by controlling the position of acoustic pressure nodes[2] that draw objects to specific locations of a standing acoustic field.[3] The target object must be considerably smaller than the wavelength of sound used, and the technology is typically used to manipulate microscopic particles.[citation needed]
Acoustic waves have been proven safe for biological objects, making them ideal for biomedical applications.[4] Recently, applications for acoustic tweezers have been found in manipulating sub-millimetre objects, such as flow cytometry, cell separation, cell trapping, single-cell manipulation, and nanomaterial manipulation.[5] The use of one-dimensional standing waves to manipulate small particles was first reported in the 1982 research article "Ultrasonic Inspection of Fiber Suspensions".[6]
In a standing acoustic field, objects experience an acoustic-radiation force that moves them to specific regions of the field.[2] Depending on an object's properties, such as density and compressibility, it can be induced to move to either acoustic pressure nodes (minimum pressure regions) or pressure antinodes (maximum pressure regions).[3] As a result, by controlling the position of these nodes, the precise movement of objects using sound waves is feasible. Acoustic tweezers do not require expensive equipment or complex experimental setups.[citation needed]
Particles in an acoustic field can be moved by forces originating from the interaction among the acoustic waves, fluid, and particles. These forces (including acoustic radiation force, secondary field force between particles, and Stokes drag force) create the phenomena of acoustophoresis, which is the foundation of the acoustic tweezers technology.
When a particle is suspended in the field of a sound wave, an acoustic radiation force that has risen from the scattering of the acoustic waves is exerted on the particle. This was first modeled and analyzed for incompressible particles in an ideal fluid by Louis King in 1934.[7] Yosioka and Kawasima calculated the acoustic radiation force on compressible particles in a plane wave field in 1955.[8] Gorkov summarized the previous work and proposed equations to determine the average force acting on a particle in an arbitrary acoustical field when its size is much smaller than the wavelength of the sound.[2] Recently, Bruus revisited the problem and gave detailed derivation for the acoustic radiation force.[9]
As shown in Figure 1, the acoustic radiation force on a small particle results from a non-uniform flux of momentum in the near-field region around the particle, [math]\displaystyle{ \mathbf{\mathit{F^{rad}}}=-\nabla\mathit{U} }[/math], which is caused by the incoming acoustic waves and the scattering on the surface of the particle when acoustic waves propagate through it. For a compressible spherical particle with a diameter much smaller than the wavelength of acoustic waves in an ideal fluid, the acoustic radiation force can be calculated by [math]\displaystyle{ \mathbf{\mathit{F^{rad}}}=-\nabla\mathit{U} }[/math], where [math]\displaystyle{ \mathit{U} }[/math] is a given quantity, also called acoustic potential energy.[2][9] The acoustic potential energy is expressed as:
[math]\displaystyle{ U = {V_0}({{\overline {p_{in}^2} } \over {2{\rho _f}c_f^2}}{f_1} - {{3{\rho _f}\overline {v_{in}^2} } \over 4}{f_2}) }[/math]
where
The coefficients [math]\displaystyle{ \mathit{f_{\mathit{1}}} }[/math] and [math]\displaystyle{ \mathit{f_{\mathit{2}}} }[/math] can be calculated by [math]\displaystyle{ {f_1} = 1 - {{{\rho _f}c_f^2} \over {{\rho _p}c_p^2}} }[/math] and [math]\displaystyle{ {f_2} = {{2({\rho _p} - {\rho _f})} \over {2{\rho _p} + {\rho _f}}} }[/math]
where
The standing waves can form a stable acoustic potential energy field, so they are able to create stable acoustic radiation force distribution, which is desirable for many acoustic tweezers applications. For one-dimension planar standing waves, the acoustic fields are given by:[9]
[math]\displaystyle{ {A_{in}}(x,t) = {{{-P_0}} \over {{\rho _f}\omega }}\sin (kx)\sin (\omega t) }[/math],
[math]\displaystyle{ {p_{in}}(x,t) = {P_0}\cos (kx)\sin (\omega t) }[/math],
[math]\displaystyle{ \textbf{v}_\textbf{in}(x,t)=\frac{-P_{0}}{\rho_{f}c_{f}}\sin(kx)\cos(\omega t))\textbf{e}_{\textbf{x}} }[/math],
where
With these fields, the time-average terms can be obtained. These are:
[math]\displaystyle{ \overline {p_{in}^2} = {1 \over 2}P_0^2{\cos ^2}(kx) }[/math],
[math]\displaystyle{ \overline {v_{in}^2} = {{P_0^2} \over {2\rho _f^2c_f^2}}{\sin ^2}(kx) }[/math],
Thus, the acoustic potential energy is:
[math]\displaystyle{ U = {V_0}{{P_0^2} \over {4{\rho _f}c_f^2}}[{\cos ^2}(kx){f_1} - {3 \over 2}{\sin ^2}(kx){f_2}] }[/math],
Then, the acoustic radiation force is found by differentiation:
[math]\displaystyle{ {F_x}^{rad} = - {\partial _x}U = {V_0}k{E_{ac}}\sin (2kx)\Phi }[/math],
[math]\displaystyle{ {E_{ac}} = {{P_0^2} \over {4{\rho _f}c_f^2}} }[/math], [math]\displaystyle{ \Phi = {f_1} + {3 \over 2}{f_2} = {{5{\rho _p} - 2{\rho _f}} \over {2{\rho _p} + {\rho _f}}} - {{{\rho _f}c_f^2} \over {{\rho _p}c_p^2}} }[/math],
where
The term [math]\displaystyle{ \sin(\mathit{2kx}) }[/math] shows that the radiation force period is one-half of the pressure period. Also, the contrast factor can be positive or negative depending on the properties of particles and fluid. For positive value of [math]\displaystyle{ \Phi }[/math], the radiation force points from the pressure antinodes to the pressure nodes, as shown in Figure 2, and the particles will be pushed to the pressure nodes.
When multiple particles in a suspension are exposed to a standing wave field, they will not only experience acoustic radiation force, but also secondary acoustic forces caused by waves scattered by other particles. The inter-particle forces are sometimes called Bjerknes forces. A simplified equation for the inter-particle forces of identical particles is:[10][11]
[math]\displaystyle{ {F_B}(x) = 4\pi {a^6}[{{{{({\rho _p} - {\rho _f})}^2}(3{{\cos }^2}\theta - 1)} \over {6{\rho _f}{d^4}}}{v_{in}}^2(x) - {{\omega^2 {\rho _f}} \over {9{d^2}}}{({1 \over {{\rho _p}c_p^2}} - {1 \over {{\rho _f}c_f^2}})^2}p_{in}^2(x)] }[/math]
where
The sign of the force represents its direction: a negative sign for an attractive force, and a positive sign for a repulsive force. The left side of the equation depends on the acoustic particle velocity amplitude [math]\displaystyle{ \mathit{v}_{\mathit{in}}(\mathit{x}) }[/math] and the right side depends on the acoustic pressure amplitude [math]\displaystyle{ \mathit{p}_{\mathit{in}}(\mathit{x}) }[/math]. The velocity-dependent term is repulsive when particles are aligned with wave propagation (Θ=0°), and negative when perpendicular to wave propagation (Θ=90°). The pressure-dependent term is unaffected by the particle orientation and is always attractive. In the case of a positive contrast factor, the velocity-dependent term diminishes as particles are driven to the velocity node (pressure antinode), as in the case of air bubbles and lipid vesicles. In a similar way, the pressure-dependent term diminishes as particles are driven towards the pressure node (velocity antinode), as are most solid particles in aqueous solutions.
In addition to the scattering-related secondary acoustic forces, the flow field resulting from the interactions of the various acoustic streaming fields, generated by the acoustic boundary layer of each particle (sometimes called microstreaming), can induce additional viscous shear forces on each of the particles' surfaces, which then results in an additional contribution to the secondary acoustic forces in its fully viscous formulations.[12] The viscous effects on the secondary acoustic force can become significant when compared to the perfect fluid formulation exemplified above, and even dominant in certain limit cases, yielding both quantitatively and qualitatively different results than what is predicted by inviscid theory.[13] The relevance of the viscous contributions varies greatly depending on the specific case being investigated, and thus important care needs to be taken in selecting an appropriate secondary acoustic force model for the given scenario.
The influence of the secondary forces is usually very weak, and only has an effect when the distance between particles is very small. It becomes important in aggregation and sedimentation applications, where particles are initially gathered in nodes by the acoustic radiation force. As inter-particle distances become smaller, the secondary forces assist in further aggregation until the clusters become heavy enough for sedimentation to begin.
Acoustic streaming is a steady flow generated by the nonlinear component of the oscillations in an acoustic field.[further explanation needed] Depending on the mechanisms, the acoustic streaming can be categorized into two general types, Eckart streaming and Rayleigh streaming.[14][15] Eckart streaming is driven by a time-average momentum flux created when high-amplitude acoustic waves propagate and attenuate in a fluid. Rayleigh streaming, also called "boundary driven streaming", is forced by Reynolds stresses in the viscous boundary layer. Both of the driven mechanisms come from a time-average nonlinear effect.
A perturbation approach is used to analyze the phenomenon of nonlinear acoustic streaming.[16] The governing equations for this problem are mass conservation and Navier-Stokes equations:
[math]\displaystyle{ \partial_{\mathit{t}}\mathit{\rho}=-\nabla\cdot (\mathit{\rho} \textbf{v}) }[/math],
[math]\displaystyle{ \mathit{\rho}[\partial _{\mathit{t}}\textbf{v}+(\textbf{v}\cdot \nabla)\textbf{v}]=-\nabla \mathit{p}+\mathit{\mu} \nabla^{2}\textbf{v}+\mathit{\beta} \mathit{\mu}\nabla(\nabla\cdot \textbf{v})) }[/math]
where
The perturbation series can be written as [math]\displaystyle{ p = {p_0} + {p_1} + {p_2} }[/math], [math]\displaystyle{ \textbf{v}=\textbf{0}+\textbf{v}_{\textbf{1}}+\textbf{v}_{\textbf{2}} }[/math], [math]\displaystyle{ \mathit{\rho}=\mathit{\rho}_{0}+\mathit{\rho}_{1}+\mathit{\rho}_{2} }[/math], which are diminishing series with the higher-order terms much smaller than the lower-order ones.
The liquid is quiescent and homogeneous at its zero-order state. Substituting the perturbation series into the mass conservation and Navier-Stokes equation and using the relation of [math]\displaystyle{ {p_1} = c_f^2{\rho _1} }[/math], the first-order equations can be obtained by collecting terms in first-order,
[math]\displaystyle{ \partial_{\mathit{t}}\mathit{p}_{1}=-\mathit{\rho}_{0}\mathit{c}_{\mathit{f}}^{2}\nabla\cdot\textbf{v}_{\textbf{1}} }[/math],
[math]\displaystyle{ \mathit{\rho}_{0}\partial _{\mathit{t}}\textbf{v}_{\textbf{1}}=-\nabla\mathit{p}_{1}+\mathit{\mu}\nabla^{2}\textbf{v}_\textbf{1}+\mathit{\beta}\mathit{\mu}\nabla(\nabla\cdot\textbf{v}_\textbf{1}) }[/math].
Similarly, the second-order equations can be found as well,
[math]\displaystyle{ \partial _{\mathit{t}}\mathit{\rho}_{2}=-\mathit{\rho}_{0}\nabla\cdot\textbf{v}_\textbf{2}-\nabla\cdot(\mathit{\rho}_{1}\textbf{v}_{\textbf{1}}) }[/math],
[math]\displaystyle{ \mathit{\rho}_{0}\partial _{\mathit{t}}\textbf{v}_{\textbf{2}}=-\nabla \mathit{p}_{2}+\mathit{\mu}\nabla^{2}\textbf{v}_{\textbf{2}}+\mathit{\beta}\mathit{\mu}\nabla(\nabla\cdot\textbf{v}_{\textbf{2}})-\mathit{\rho}_{1}\partial _{t}\textbf{v}_{\textbf{1}}-\mathit{\rho}_{0}(\textbf{v}_{\textbf{1}}\cdot\nabla)\textbf{v}_{\textbf{1}} }[/math].
For the first-order equations, taking the time derivation of the Navier-Stokes equation and inserting the mass conservation, a combined equation can be found:
[math]\displaystyle{ {1 \over {c_f^2}}\partial _t^2{p_1} = [1 - {{(1 - \beta )\mu } \over {{\rho _0}c_f^2}}{\partial _t}]{\nabla ^2}{p_1} }[/math].
This is an acoustic wave equation with viscous attenuation. Physically, [math]\displaystyle{ \mathit{p}_{1} }[/math] and [math]\displaystyle{ \textbf{v}_{\textbf{1}} }[/math] can be interpreted as the acoustic pressure and the velocity of the acoustic particle.
The second-order equations can be considered as governing equations used to describe the motion of fluid with mass source [math]\displaystyle{ [-\nabla\cdot(\mathit{\rho}_{1}\textbf{v}_{\textbf{1}}))] }[/math] and force source [math]\displaystyle{ [-\rho_{1}\partial _{t}\textbf{v}_{\textbf{1}}-\rho_{0}(\textbf{v}_{\textbf{1}}\cdot\nabla)\textbf{v}_{\textbf{1}}] }[/math]. Generally, the acoustic streaming is a steady mean flow, where the response time scale is much smaller than the one of the acoustic vibration. The time-average term [math]\displaystyle{ \overline{\textbf{v}_{\textbf{2}}} }[/math] is normally used to present the acoustic streaming. By using [math]\displaystyle{ \overline{\partial _{\mathit{t}}\mathit{\rho}_{2} }=0 }[/math], the time-average second-order equations can be obtained:
[math]\displaystyle{ \mathit{\rho}_{0}\nabla\cdot\overline{\textbf{v}_{\textbf{2}}}=-\nabla\cdot\overline{(\mathit{\rho}_{1}\textbf{v}_{\textbf{1}})} }[/math],
[math]\displaystyle{ \mathit{\mu}\nabla^{2}\overline{\textbf{v}_{\textbf{2}}}+\mathit{\beta}\mathit{\mu}\nabla(\nabla\cdot\overline{\textbf{v}_{\textbf{2}}})-\overline{\nabla \mathit{p}_{2}}=\overline{\mathit{\rho}_{1}\partial _{\mathit{t}}\textbf{v}_{\textbf{1}}}-\mathit{\rho}_{0}\overline{(\textbf{v}_{\textbf{1}}\cdot\nabla)\textbf{v}_{\textbf{1}}} }[/math].
It is important to note that the time-averaging of pure first-order terms lead to their cancellation, since they are by definition harmonic. This means that they are pure sine waves, and thus have a mean of 0, which leads to the cancellation of any term that contains them. Second-order terms are, however, not harmonic, and do not get cancelled out by time-averaging.[17] This is most important for understanding acoustic streaming: first-order terms, related to simple oscillatory motion, have much larger magnitudes than second-order terms, and thus are dominant in the oscillation time-scale. Those first-order terms, however, being pure sines, in a quasi-steady state, repeat after each oscillation cycle, yielding no net fluid flow. Second-order terms, instead, are not harmonic, and thus can have a cumulative effect which, despite being smaller, can add up over many oscillation cycles, leading to the development of the net steady-state flow we identify as acoustic streaming.
In determining the acoustic streaming, the second-order equations are thus most important. Since Navier-Stokes equations can only be analytically solved for simple cases, numerical methods are typically used, with the finite element method (FEM) the most common technique. It can be employed to simulate the acoustic streaming phenomena. Figure 3 is one example of acoustic streaming around a solid circular pillar, which is calculated by FEM.
As mentioned, acoustic streaming is driven by mass and force sources originating from the acoustic attenuation. However, these are not the only driven forces for acoustic streaming. The boundary vibration may also contribute, especially to "boundary driven streaming". For these cases, the boundary condition should also be processed by the perturbation approach and be imposed on the two order equations accordingly.
The motion of a suspended particle whose gravity is balanced by the buoyancy force in an acoustic field is determined by two forces: the acoustic radiation force and Stokes drag force. By applying Newton's law, the motion can be described as:
[math]\displaystyle{ \mathit{m}\frac{d\textit{u}}{\mathit{d t}}=\textit{F}^{\textit{rad}}+\textit{F}^{\textit{drag}} }[/math],
[math]\displaystyle{ \textit{F}^{\textit{drag}}=6\pi \mathit{a}\mathit{\mu}(\textit{v}-\textit{u}) }[/math].
where
For applications in a static flow, the fluid velocity comes from the acoustic streaming. The magnitude of acoustic streaming depends on the power and frequency of the input and the properties of the fluid media. For typical acoustic-based microdevices, the operating frequency may be from the kHz to the MHz range. The vibration amplitude is in a range of 0.1 nm to 1 μm. Assuming the fluid used is water, the estimated magnitude of acoustic streaming is in the range of 1 μm/s to 1 mm/s. Thus, the acoustic streaming should be smaller than the main flow for most continuous flow applications. The drag force is mainly induced by the main flow in those applications.
This section has multiple issues. Please help improve it or discuss these issues on the talk page. (Learn how and when to remove these template messages)
(Learn how and when to remove this template message)
|
Cells with different densities and compression strengths can theoretically be separated with acoustic force. It has been suggested that acoustic tweezers could be used to separate lipid particles from red blood cells.[18] This is a problem during cardiac surgery supported by a heart-lung machine, for which current technologies are insufficient. According to the proposal, acoustic force applied to blood plasma passing through a channel will cause red blood cells to gather in the pressure node in the center and the lipid particles to gather in antinodes at the sides (see Figure 4). At the end of the channel, the separated cells and particles exit through separate outlets.
The acoustic method might also be used to separate particles of different sizes. According to the equation of primary acoustic radiation force, larger particles experience larger forces than smaller particles. Shi et al. reported using interdigital transducers (IDTs) to generate a standing surface acoustic wave (SSAW) field with pressure nodes in the middle of a microfluidic channel, separating microparticles with different diameters.[19] When introducing a mixture of particles with different sizes from the edge of the channel, larger particles will migrate toward the middle more quickly and be collected at the center outlet. Smaller particles will not be able to migrate to the center outlet before they are collected from the side outlets. This experimental setup has also been used to separate blood components, bacteria, and hydrogel particles.[20][21][22]
Fluorescence-activated cell sorters (FACS) can sort cells by focusing a fluid stream containing the cells, detecting fluorescence from individual cells, and separating the cells of interest from other cells. They have high throughput but are expensive to purchase and maintain, and are bulky with a complex configuration. They also affect cell physiology with high shear pressure, impact forces and electromagnetic forces, which may result in cellular and genetic damage. Acoustic forces are not dangerous to cells,[citation needed] and there has been progress integrating acoustic tweezers with optical/electrical modules for simultaneous cell analysis and sorting, in a smaller and less-expensive machine.
Acoustic tweezers have been developed to achieve 3D focusing of cells/particles in microfluidics.[23] A pair of interdigital transducers (IDTs) are deposited on a piezoelectric substrate, and a microfluidic channel is bonded with the substrate and positioned between the two IDTs. Microparticle solutions are infused into the microfluidic channel by a pressure-driven flow. Once an RF signal is applied to both IDTs, two series of surface acoustic waves (SAW) propagate in opposite directions toward the particle suspension solution inside the microchannel. The constructive interference of the two SAWs results in the formation of a SSAW. Leakage waves in the longitudinal mode are generated inside the channel, causing pressure fluctuations that act laterally on the particles. As a result, the suspended particles inside the channel will be forced toward either the pressure nodes or antinodes, depending on the density and compressibility of the particles and the medium. When the channel width covers only one pressure node (or antinode), the particles will be focused in that node.
In addition to focusing in a horizontal direction, cells/particles can also be focused in the vertical direction.[24] After SSAW is on, the randomly distributed particles are focused into a single file stream (Fig. 10c) in the vertical direction. By integrating a standing surface acoustic wave (SSAW)-based microdevice capable of 3D particle/cell focusing with laser-induced fluorescence (LIF) detection system, acoustic tweezers are developed into a microflow cytometer for high-throughput single cell analysis.
The tunability offered by chirped[clarification needed] interdigital transducers[25][26] renders it capable of precisely sorting cells into a number (e.g., five) of outlet channels in a single step. This is a major advantage over most existing sorting methods, which typically only sort cells into two outlet channels.
A glass reflector with etched fluidic channels is clamped to the PCB holding the transducer. Cells infused into the chip are trapped in the ultrasonic standing wave formed in the channel. The acoustic forces focus the cells into clusters in the center of the channel as illustrated in the inset. Since the trapping occurs close to the transducer surface, the actual trapping sites are given by the near-field pressure distribution as shown in the 3D image. Cells will be trapped in clusters around the local pressure minima creating different patterns depending on the number of cells trapped. The peaks in the graph correspond to the pressure minima.
Manipulating single cells is important to many biological studies, such as in controlling the cellular microenvironment and isolating specific cells of interest. Acoustic tweezers have been demonstrated to manipulate each individual cell with micrometer-level resolution. Cells generally have a diameter of 10–20 μm. To meet the resolution requirements of manipulating single cells, short-wavelength acoustic waves should be employed. In this case, a surface acoustic wave (SAW) is preferred to a bulk acoustic wave (BAW), because it allows using shorter-wavelength acoustic waves (normally less than 200 μm).[27] Ding et al. reported a SSAW microdevice that is able to manipulate single cells with prescribed paths.[28] Figure 6 records a demonstration that the movement of single cells can be finely controlled with acoustic tweezers. The working principle of the device lies in the controlled movement of pressure nodes in an SSAW field. Ding et al. employed chirped interdigital transducers (IDTs) that are able to generate SSAWs with adjustable positions of pressure nodes by changing the input frequency. They also showed that the millimeter-sized microorganism C. elegan can be manipulated in the same manner. They also examined cell metabolism and proliferation after acoustic treatment, and found no significant differences compared to the control group, indicating the non-invasive nature of acoustic base manipulation. In addition to using chirped IDTs, phaseshift-based single particle/cell manipulation has also been reported.[29][30][31]
Sitters et al. have shown that acoustics can be used to manipulate single biomolecules such as DNA and proteins. This method, which the inventors call acoustic force spectroscopy, allows measuring the force response of single molecules. This is achieved by attaching small microspheres to the molecules at one side and attaching them to a surface at the other. By pushing the microspheres away from the surface with a standing acoustic wave the molecules are effectively stretched out.[32]
Polymer-dispersed liquid crystal (PDLC) displays can be switched from opaque to transparent using acoustic tweezers. A SAW-driven PDLC light shutter has been demonstrated by integrating a cured PDLC film and a pair of interdigital transducers (IDTs) onto a piezoelectric substrate.[33]
Acoustic tweezers provide a simple approach for tuneable nanowire patterning. In this approach, SSAWs are generated by interdigital transducers, which induced a periodic alternating current (AC) electric field on the piezoelectric substrate and consequently patterned metallic nanowires in suspension. The patterns could be deposited onto the substrate after the liquid evaporated. By controlling the distribution of the SSAW field, metallic nanowires are assembled into different patterns including parallel and perpendicular arrays. The spacing of the nanowire arrays could be tuned by controlling the frequency of the surface acoustic waves.[34]
While most acoustic tweezers are able to manipulate a large number of objects collectively,[27] a complementary function is to be able to manipulate a single particle within a cluster without moving adjacent objects. To achieve this goal, the acoustic trap must be localized spacially. A first approach consists in using highly focused acoustic beams.[35] Since many particles of interest are attracted to the nodes of an acoustic field and thus expelled from the focus point, some specific wave structures combining strong focalization but with a minimum of the pressure amplitude at the focal point (surrounded by a ring of intensity to create the trap) are required to trap this type of particle. These specific conditions are met by Bessel beams of topological order larger than zero, also called "acoustical vortices". With this kind of wave structures, the 2D[36] and 3D[37][38] selective manipulation of particles has been demonstrated with an array of transducers driven by programmable electronics.
Alternatively, another approach to localize the acoustic energy relies on the use of nanosecond-scale pulsed fields to generate localized acoustic standing waves.[39]
The individual selective manipulation of micro-objects requires to synthesize complex acoustic fields such as acoustic vortices (see previous section) at sufficiently high frequency to reach the necessary spatial resolution (typically the wavelength must be comparable to the size of the manipulated object to be selective). Many holographic methods have been developed to synthesize complex wavefields including transducer arrays,[40][41][36][42][38] 3D printed holograms,[43] metamaterials [44] or diffraction gratings.[45][46] Nevertheless, all these methods are limited to relatively low frequencies with an insufficient resolution to address micrometric particles, cells or microorganisms individually. On the other hand, InterDigitated Transducers (IDTs) were known as a reliable technique to synthesize acoustic wavefields up to GHz frequency.[47]
Original source: https://en.wikipedia.org/wiki/Acoustic tweezers.
Read more |